SPECIFICATION BY R&D BKL 200 ICE EF BKL 200 ICE EF Heavy Duty BKL 200 DUO EF BIC INDUSTRIAL WATER CHILLER
CAPACITY The number of litres per hour that can be re-cooled to 15 degrees Celsius (non-recurrent) 40-150 L/HOUR 40-250 L/HOUR 40-400 L/HOUR 300 - NO MAXIMUM
TEMPERATURE WITH ONE UNIT The lowest re-cooling temperature 1,5 ºC - 3ºC 1,5 ºC - 3ºC 0,5 ºC - 3ºC 2 ºC - 4ºC or any other
SPEED (DEPENDING ON WATER PRESSURE) The highest number of litres per minute that can be processed through heat exchangers 12-20 L/MIN 12-20 L/MIN 12-30 L/MIN 40 L/MIN - NO LIMIT
COMPRESSOR The power of the compressor, expressed in hp (horse power) ½ HP 2 x ⅜ HP 1 HP (2 x ½ HP) UPOREQUEST
ICE MASS The maximum weight of the cold buffer, accumulated at rest (extra capacity) 40 KG 40 KG 80 KG (2 x 40 KG) UPON REQUEST
COOLANT The chemical substance used to transport heat R290 R290 R290 UPON REQUEST
AMOUNT OF REFRIGERANT The total amount of refrigerant (R290) charged to the cooling system 125 grams 2 x 94 grams 2 x 125 grams UPON REQUEST
NET VOLUME OF WATER BATH The maximum content of the water bath (the water is only for cold transfer) 72 LITRES 72 LITRES 144 LITRES (2 x 72 LITRES) UPON REQUEST
ELECTRICITY The required connected loads with which the device should be connected to the electrical network (please note: this may differ per country, region, or production environment) 220-240 VAC / 50 Hz 220-240 VAC / 50 Hz 220-240 VAC / 50 Hz UPON REQUEST
POWER CONSUMPTION the required connected loads with which the device should be connected to the electrical network (please note: this may differ per country, region, or production environment) 650 W 870 W 2 x 650 W UPON REQUEST
CURRENT the required connected loads with which the device should be connected to the electrical network (please note: this may differ per country, region, or production environment) 4,2 A 5,6 A 2 x 4,2 A UPON REQUEST
WATER PRESSURE The minimum and maximum continuous water pressure that is required for the optimum operation of the device in kg per cm2 / bar 1-5 KG/CM² 1-5 KG/CM² 1-5 KG/CM² UPON REQUEST
MAXIMUM TEST PRESSURE The maximum pressure at which the device has been tested 16 KG/CM² 16 KG/CM² 10 KG/CM² UPON REQUEST
WATER INLET DIAMETER The weight of the machine, excluding water and packaging R ½" R ½" R ½" UPON REQUEST
NETT WEIGHT The weight of the machine, excluding water and packaging 71 KG 82 KG 95 KG UPON REQUEST
DIMENSIONS The dimensions of the machine, excluding connections 50 x 53.5 x 87 CM 50 x 53.5 x 90.5 CM 100 x 53.5 x 94 CM UPON REQUEST